Pamtc,comp,verify – Airmar PB200 User Manual

Page 127

Advertising
background image

PB200 WeatherStation User Manual revision 1.000

Proprietary and Confidential

121

$PAMTC,COMP,VERIFY

Summary

Verify the user compass calibration mode.

Syntax

$PAMTC,COMP,VERIFY*hh<CR><LF>

The verify user calibration sequence for the PB200 is as follows:

1.

The weather station is installed on the vessel. The unit under test is powered up.

User calibration has been completed successfully.

2.

The $PAMTC,COMP,VERIFY*hh<CR><LF> command is sent to the

weather station’s NMEA 0183 input channel to initiate user calibration mode.

3.

During the verify user calibration process, the vessel is rotated slowly (driven in

a circle) and the sensor calculates the resulting score. Once the weather station

has determined that enough data has been collected, it transmits the following
sentence: $PAMTR,COMP,SCORE,XXX*hh<CR><LF>

Reply

The weather station will reply immediately with:
$PAMTR,COMP,INPROGRESS,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh<CR><LF>
Where fields <1> through <9> contain the data from the weather station’s

nonvolatile EEPROM, as defined in the “Q”, Query Command.
Upon successful completion the weather station will reply with:
$PAMTR,COMP,SCORE,XXX*hh<CR><LF>

Where XXX is a score from 0 – 255, meaning TBD.


Or, upon failure it will reply with:
$PAMTR,COMP,FAILx,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh<CR><LF>

Where x indicates the type of failure, 1 = Timeout, 2 = Tilt Error, or 3 = Other

Error.