0x1ef00), Proprietary: received pgn source – Airmar PB200 User Manual

Page 36

Advertising
background image

PB200 WeatherStation User Manual revision 1.000

Proprietary and Confidential

30

NMEA 2000® TRANSMITTED PARAMETER GROUP

PGN

126720-47

(0x1EF00)

Proprietary: Received PGN Source

Single Frame: No

Priority: 7/Y/N

Update Rate: 0/N/N

Destination: Address

Query Support: Yes

Access Level: 0

Field

#

Name

Request

Param. DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

Yes

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar

Technology.

2 Reserved bits

No

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

Yes

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine

Industry".

4 Proprietary ID (PID)

Yes

DD005 DF53 uint8

1 bit

47 (decimal)

47 = Received PGN Source

5 Received PGN number

Yes

DD009 DF52 24 bits

1

128259 only (for PB200)

24-bit Parameter Group Number

(PGN) expressed in binary, LSB is

transmitted first.

6 Rule

No

DD003 DF52 3 bits

1

0 = Reserved

1 = Highest priority Airmar device

2 = Highest priority device, any mfr.

3 = Specific device

4 = Specific device, or highest priority
5-6 = Reserved
7 = No action/Data Not Available

The default value for this field is 1.

This field is saved in EEPROM.

See the text below for an

explanation of this field.

7 Reserved bits

No

DD001 DF52 5 bits

1

0x1F

All bits set to logic "1"

8 CAN name

No

N/A DF52 64 bits

1

Variable

CAN name for the specific

transmitting device intended to

provide the PGN specified in field

5. The CAN name is supplied by

the address claim PGN 60928 of the

transmitting device. This field is

saved in EEPROM.

Advertising
This manual is related to the following products: