Figure – H3C Technologies H3C S6800 Series Switches User Manual

Page 14

Advertising
background image

6

The flood proxy mode applies to VXLANs that have many sites. This mode reduces flood traffic in

the transport network without using a multicast protocol. To use a flood proxy server, you must set
up a VXLAN tunnel to the server on each VTEP.

NOTE:

The flood proxy mode is typically used in SDN transport networks that have a flood proxy server. For
VTEPs to forward packets based on the MAC address table issued by an SDN controller, you must
perform the following tasks on the VTEPs:

Disable remote-MAC address learning by using the vxlan tunnel mac-learning disable command.

Configure an OpenFlow instance for the VXLAN.

Each destination VTEP floods the inner Ethernet frame to all the site-facing interfaces in the VXLAN. To

avoid loops, the destination VTEPs do not flood the frame to VXLAN tunnels.

Figure 5 Unicast mode

VTEP 1

VTEP 2

Transport network

P

Server 1

VM 1

VM 2

VM 3

Server 3

VM 7

VM 8

VM 9

Server 2

VM 4

VM 5

VM 6

FGE1/0/1

FGE1/0/2

FGE1/0/1

VX

LA

N tu

nne

l

VTEP 3

VXLAN tunnel

Server 4

VM 10

VM 11

VM 12

Replicate and
encapsulate

Advertising