# Enable IP multicast routing.

<SwitchF> system-view

[SwitchF] multicast routing

[SwitchF-mrib] quit

# Enable PIM-SM on VLAN-interface 21, VLAN-interface 22, and VLAN-interface 23.

[SwitchF] interface vlan-interface 21

[SwitchF-Vlan-interface21] pim sm

[SwitchF-Vlan-interface21] quit

[SwitchF] interface vlan-interface 22

[SwitchF-Vlan-interface22] pim sm

[SwitchF-Vlan-interface22] quit

[SwitchF] interface vlan-interface 23

[SwitchF-Vlan-interface23] pim sm

[SwitchF-Vlan-interface23] quit

# Enable BIDIR-PIM.

[SwitchF] pim

[SwitchF-pim] bidir-pim enable

# Configure VLAN-interface 22 as a candidate-BSR, and configure Loopback 0 as a candidate-RP
for BIDIR-PIM.

[SwitchF-pim] c-bsr 22.1.1.6

[SwitchF-pim] c-rp 6.6.6.6 bidir

[SwitchF-pim] quit

8.

Configure Switch G:
# Enable IP multicast routing.

<SwitchG> system-view

[SwitchG] multicast routing

[SwitchG-mrib] quit

# Enable IGMP on VLAN-interface 12.

[SwitchG] interface vlan-interface 12

[SwitchG-Vlan-interface12] igmp enable

[SwitchG-Vlan-interface12] quit

# Enable PIM-SM on VLAN-interface 22.

[SwitchG] interface vlan-interface 22

[SwitchG-Vlan-interface22] pim sm

[SwitchG-Vlan-interface22] quit

# Enable BIDIR-PIM.

[SwitchG] pim

[SwitchG-pim] bidir-pim enable

[SwitchG-pim] quit

Verifying the configuration

1.

Verify the VXLAN settings on the VTEPs. This example uses Switch A.
# Verify that the VXLAN tunnel interfaces on the VTEP are up.

[SwitchA] display interface tunnel 1

Tunnel1

Current state: UP

Line protocol state: UP

Advertising