61

Specifying a global source address for VXLAN

tunnels

IMPORTANT:

For correct VXLAN deployment and VTEP management, do not manually specify tunnel-specific source
addresses for VXLAN tunnels if OVSDB is used.

The VTEP reports the global VXLAN tunnel source address to the controller for VXLAN tunnel setup.
To specify a global source address for VXLAN tunnels:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Specify a global source

address for VXLAN
tunnels.

tunnel global source-address
source-address

By default, no global source address is
specified for VXLAN tunnels.

Specifying a VTEP access port

For the controller to manage a site-facing interface, you must specify the interface as a VTEP access port.
Manual configuration might affect controller management. H3C recommends that you do not perform
manual configuration on a VTEP access port.
To specify a VTEP access port:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter interface view.

Enter Layer 2 Ethernet interface
view:

interface interface-type

interface-number

Enter Layer 2 aggregate interface

view:

interface bridge-aggregation

interface-number

N/A

3.

Specify the interface as a VTEP
access port.

vtep access port

By default, an interface is not a
VTEP access port.

Disabling source MAC check

You must disable source MAC check on all transport-facing interfaces for a VXLAN if the VXLAN uses a

flood proxy server. If the VTEP is an IRF fabric, you must also disable the feature on all IRF ports.
Source MAC check drops an incoming frame if the frame meets both of the following conditions: