Vxlan is-is configuration example, Network requirements – H3C Technologies H3C S6800 Series Switches User Manual

Page 57

Advertising
background image

49

Task Command

Display remote VXLAN information
learned through VXLAN IS-IS.

display vxlan isis remote-vxlan [ [ vxlan vxlan-id ] [ count ] ]

Display VXLAN IS-IS information for
tunnel interfaces.

display vxlan isis tunnel [ tunnel-number ]

Clear data for the VXLAN IS-IS process. reset vxlan isis

VXLAN IS-IS configuration example

Network requirements

As shown in

Figure 12

:

Configure unicast-mode VXLANs on Switch A, Switch B, and Switch C to provide Layer 2
connectivity for the VMs across different sites.

Manually set up VXLAN tunnels between the VTEPs.

Configure VXLAN IS-IS to advertise MAC reachability information and automate VXLAN tunnel
assignment.

Table 4

shows the VLAN and VXLAN mapping scheme.

Table 4 VXLAN and VLAN mappings

VMs VTEPs

VLAN

VXLAN

VM 1, VM 5

Switch A, Switch B

VLAN 2

VXLAN 10000

VM 2, VM 6

Switch A, Switch B

VLAN 3

VXLAN 10001

VM 3, VM 7

Switch A, Switch C

VLAN 4

VXLAN 10002

VM 4, VM 8

Switch A, Switch C

VLAN 5

VXLAN 10003

Figure 12 Network diagram

Switch A

Switch C

IP transport

network

Switch D

FGE1/0/1

FGE1/0/1

Switch B

Server 2

Server 1

FGE1/0/1

Loop0

1.1.1.1/32

Loop0

3.3.3.3/32

Loop0

2.2.2.2/32

Vlan-int11
11.1.1.1/24

Vlan-int13
13.1.1.4/24

Vlan-int12

12.1.1.2/24

Vlan-int11

11.1.1.4/24

Vlan-int13

13.1.1.3/24

Vlan-int12

12.1.1.4/24

VM 2

VM 3

VM 4

VM 1

VM 6

VM 5

Server 2

VM 7

VM 8

VXLAN 10000

VXLAN 10001

VXLAN 10002

VXLAN 10003

Advertising