Reference input sync timing determines the output timing. If a sync
changeover is used for the sync reference, the timing of both sync
sources must match. This ensures that the timing from the 8964FS
remains consistent if the reference input sync switches.
Configuration Summary Table
provides a complete summary of the 8964FS functions and a com-
parison of the functionality available with each control type along with the
ranges and default values for each parameter.
Table 5. Summary of 8964FS Configuration Functions
Function
Type
Default
Range/Choices
Resolution
Web Page/
Function Name
Function Switch
Bank/Setting
Newton
Control
Panel
Notes/
Conditions
OSD (On Screen Display)
Off
On/Off
OSD Control/
On Screen Display
1:1
N/A
Jumper JP3
must be enabled
on module.
Horizontal Timing
0
0 - 857.5 pixels (525)
0 - 863.5 pixels (625)
(0.5 pixel steps)
Timing/
Horizontal Timing (pixels)
2:B
HTim 1-4
Vertical Timing
0
0 – 524 lines (525)
0 – 624 lines (625)
(1line steps)
Timing/
Vertical Timing (lines)
2:C
VTim1-4
Freeze Type
Auto-
Blue
AutoFreeze, AutoBlue
Field 1, Field 2, or
Frame
Timing/Freeze Mode
Select AutoFrz, AutoBlue,
Field 1, Field 2, or Frame
radio button
2:D
2:E
2:F
Frez1-4
Test Signal Generator
Disable
Disable/Color Bars
Video Proc/
Select Disable or Color Bars
radio button
1:C
Tst1-4
Video
processing
controls
Horizontal ancillary data
(HANC)
Pass
Pass or Blank
Video Proc/
Select HANC Pass or Blank
radio button
1:4
Hanc1-4
EDH Insertion
On
On/Off
Video Proc/
Select EDH Inserter On or Off
radio button
1:3
EDH 1-4
Reserve VBI lines for data
None
See
VBI/
Select data line pair buttons
2:1/2:2/2:3
N/A
See tables for
line rate choices
Blank VBI Lines
On
On/Off
VBI/
Blank VBI/Data Line Pair or use
Blank All or Pass All button
2:4
N/A
Line selectable
in Remote.
Global in Local.
Learn/Recall E-MEM
N/A
E-MEM 1-5
E-MEM/
Standard View: Recall 1-5
Advanced View: Recall/Learn
/Save to/Load from
1:E
N/A
E-MEM
functions
Recall factory defaults
N/A
See Defaults column
E-MEM/
Recall factory settings button
1:F
N/A