Status monitoring, Leds, Status monitoring on – Grass Valley 8964FS User Manual

Page 48: Refer to

Advertising
background image

48

8964FS Instruction Manual

Status Monitoring

Status Monitoring

This section provides a summary of status monitoring and reporting for a
Gecko 8900 Series system. It also summarizes what status items are
reported and how to enable/disable reporting of each item. There are a
number of ways to monitor status of modules, power supplies, fans and
other status items depending on the method of monitoring being used.

8900 Frame status will report the following items:

Power supply health

Status of fans in the frame front cover

Temperature,

Module health

Frame bus status

Module health status will report the following items:

Internal module state (and state of submodule or options enabled)
including configuration errors (warning), internal faults, and normal
operation (Pass).

Signal input states including valid/present (pass), not present or
invalid (warning), not monitored, and not available (no signal inputs).

Reference input states including locked/valid (pass), not
locked/invalid (warning), and not monitored.

LEDs

LEDs on modules in the frame and on the front of the 8900TF/TFN frames
indicate status of the frame and the installed power supplies, fans in the
front covers, and modules. (The 8900TX-V/A frames have no LED indica-
tors on the front cover.)

When a red FAULT LED is lit on a frame front cover, the fault will also be
reported on the 8900NET or Frame Monitor module. The LEDs on the front
of these modules can then be read to determine the following fault condi-
tions:

Power Supply 1 and 2 health

Fan rotation status

Frame over-temperature condition

Frame Bus fault (8900NET only)

Module health bus