8985FSP/FS/PRC — Instruction Manual

23

Configuration

Configuration

The 8985 module can only be configured remotely using the 8900NET
network interface GUI or a networked Newton control panel. The 8900NET
module must be running software version 4.0.2 or later. (See

Software

Requirements on page 11

for instructions for upgrading this software.)

Refer to the following sections for configuration instructions:

Configuration Overview (

page 23

)

Remote Control and Monitoring (

page 26

)

Configuration Parameter Summary (

page 75

)

Operation of these control types is explained in detail in their respective
sections of this manual.

Configuration Overview

This section provides a brief overview of all parameters that can be config-
ured on the 8985 module. Use this section in conjunction with the specific
configuration method instructions for each configuration type.

Table 6 on

page 75

provides a summary in table format of all parameters and their

ranges, default values, and remote web page and Newton control panel
function names and locations for setting each value.

Video Input Selection

Set the type of input connection from a coaxial electrical input or, if an
optional SFP Fiber Optic submodule is installed, one of the fiber optic
inputs.

System Configuration

System configuration is required for the input type and line rate and selec-
tion of the output timing source when the Frame Sync option is enabled.

8000GEN-SM Reference Timing

When an 8900GEN-SM submodule is installed as either a local reference to
the host module or configured to output frame buses from host modules in
slot 1 and slot 3, the genlock timing can be adjusted to match reference
timing.