75

Configuration Parameter
Summary

Table 6

provides a complete summary of the 8985FSP functions and a com-

parison of the functionality available with the web page and Newton
control panel control type along with the ranges and default values for each
parameter.

Table 6. Summary of 8985FSP Configuration Functions

Function

Type

Default

Range/Choices

Resolution

Web Page/

Function Name

Newton

Control

Panel

Reference Signal Loss Reporting

On

On or Off

I/O Config/

Genlock Ref In Loop

Reporting Enabled checkbox

N/A

Coax Input Signal Loss Reporting

On

On or Off

I/O Config/

COAX In

Reporting Enabled checkbox

N/A

Fiber Input 1 and 2 Signal Loss
Reporting

On

On or Off

I/O Config/

Fiber Video in/Out 1 and 2

Reporting Enabled checkbox

N/A

Video Input Selection

COAX

COAX,

Fiber RX 1,

or Fiber RX 2

Video In/

Video Input Select

Video Input Selection

radio button

N/A

Input video type

HD 59.94

HD 59.94,

SD,

HD 50, or

HD 24

System Config/

Input Video

Input Rate radio button

N/A

Input video rate

1080i

HD 59.94:

1080i/59.94 or 720p/59.94

SD:

480i/59.94 or 576i/50

HD 50:

1080i/50 or 720p/50

HD 24:

1080sf/24 or 1080p/24

System Config/

Input Video

Input Type pulldown

N/A

Select primary output

timing source

Local

Local,

Ref 1,
Ref 2,

or Input

System Config/

Output Timing

Primary Source Selection

radio button

OutClk

Select secondary output timing
source

Local

Local,

Ref 1,
Ref 2,

or Input

System Config/

Output Timing

Secondary Source Selection

radio button

OutClk

Test Output Color Bars signal

Disabled

Enable or Disable

System Config/

Test Output

Colorbars Enabled checkbox

ClrBars