Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 178

Advertising
background image

Related Links

Configuring reference file type on a K2 SAN system

on page 281

Configure iSCSI Bridge Server Configuration page - Redundant K2 SAN server B

This page manages the components that bridge between iSCSI (the GigE media network) and the
Fibre Channel connection to the RAID storage. You configure network settings on the iSCSI adapters
and the page validates that the Fibre Channel adapter is in place and that the media RANKs are
visible as iSCSI targets.

NOTE: The iSCSI adapters on this server must be on a different subnet than those on its
redundant server partner.

1. Select

Backup

.

2. Select an iSCSI adapter and do the following:

a) Click

Modify

.

A network configuration dialog box opens.

b) Verify or enter the media network IP address and the subnet mask.
c) Click

Apply

.

3. Repeat the previous step for the other iSCSI adapters.

178

K2 SAN Installation and Service Manual

18 November 2010

Configuring and licensing the K2 SAN

Advertising