K2 raid for basic nearline k2 san, Cabling k2 san devices – Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 60

Advertising
background image

Primar y

Expansion 1

Expansion 2

DP0

DP1

To

Expansion

3

To

Expansion

4

DP0

DP1

To

Expansion

3

To

Expansion

4

To K2 Media
Server A

To K2 Media
Server B

To control port
on GigE switch A

To control port
on GigE switch B

Contr oller 1

Contr oller 0

SAS cable connectors are keyed

to DP IN/OUT ports.

SAS cables

NOTE: Do not connect the controller MNT port. It should only be used
with a PC in a peer-to-peer connection for diagnostics purposes.

If you have more Expansion chassis than those illustrated, continue the indicated cabling pattern,
alternating connections for additional Expansion chassis between DP1 and DP0. Expansion chassis
1, 3, 5, 7, etc. (odd numbers) connect to DP1. Expansion chassis 2, 4, 6, 8, etc. (even numbers)
connect to DP0. For example, if you have four Expansion chassis (an even number), they are evenly
balanced, so you have two connected to DP1 and two connected to DP0. If you have five Expansion
chassis (an odd number), the “plus one” Expansion chassis is always connected to DP1, so you have
three connected to DP1 and two connected to DP0.

K2 RAID for basic nearline K2 SAN

These cabling instructions apply to the following:

K2 RAID (Condor with 10G controllers) on a basic nearline K2 SAN.

60

K2 SAN Installation and Service Manual

18 November 2010

Cabling K2 SAN devices

Advertising