Trinix NXT — Installation and Service Manual

Section 2 — Planning Guide

Voltage Range:

100-240 VAC 50-60 Hz, universal, auto-ranging (fuses must be
selected and installed as appropriate for mains voltage) For
fuses F101, F105, F110- F113, F201, F205, and F210-F213 replace
with fuse rated “5A 125V Fast Acting” (GV PN: 59-5053-00,
LITTELFUSE PN: 39515000440) These fuses are accessible from
the rear panel (underneath the two fuse covers on the rear of
chassis).

Operating Current

: The Operating current will vary depending on the specific con-

figuration of the router. The two cases below will serve as a ref-
erence.

CASE A: Fully configured system

DV-33128 and NXT-128

5.7 A @ 120 VAC and 2.9 A @ 240 VAC

DV-33256 and NXT-256

10 A @ 120 VAC and 5 A @ 240 VAC

DV-33512 and NXT-512

20 A @ 120 VAC and 10 A @ 240 VAC

TRX-NXT-128x256

10 A @ 120 VAC and 5 A @ 240 VAC

TRX-NXT-256x512

19 A @ 120 VAC and 10 A @ 240 VAC

CASE B: Fully configured system that is operating in boosted
mode.

DV-33128 and NXT-128

6 A @ 120 VAC and 3 A @ 240 VAC

DV-33256 and NXT-256

12.5 A @ 120 VAC and 6.3 A @ 240 VAC

DV-33512 and NXT- 512
25 A @ 120 VAC and 12.6 A @ 240 VAC

TRX-NXT-128x256

12 A @ 120 VAC and 6.3 A @ 240 VAC

TRX-NXT-256x512

20 A @ 120 VAC and 10 A @ 240 VAC

TRX-NXT-512x1024

20 A @ 120 VAC and 10 A @ 240 VAC

Inrush Current

128 x 128 frame: 49.05 A
256 x 256 frame: 55.0 A
512 x 512 frame: 45 A