Output expansion, Input and output expansion – Grass Valley Trinix NXT v.3.3.1 User Manual

Page 89

Advertising
background image

Trinix NXT — Installation and Service Manual

89

Duplication and Expansion

The concepts in this example can be applied equally to both HD and SD
systems with PE-33008 Port expanders. For example, they would apply to
a 1024 x 1024 system that is pre-wired for expansion to 2048 x 1024 (similar
to the system shown in

Figure 37 on page 79

, where LD-33100 Loader

boards would be installed in place of output boards in Frames 4 through 7).

Output Expansion

The LD-33100 Loader boards may also be used for output-expandable sys-
tems. For example,

Figure 48 on page 89

, below shows a 512 x 512 system

expandable to 512 x 1024:

Figure 48. A 512 X 512 System Expanded to 512 x 1024

Again, considering one signal path (below in

Figure 49

), pre-wired cable

connections do not allow for installation of individual terminators. Instead,
the LD-33100 Loader boards are installed in the unused frame. However, in
this case they are installed in the input slots.

Figure 49. Detail of one PE-33016 shown above in

Figure 48

Input and Output Expansion

The rules just described for use of LD-33100 Loader boards will also apply
to systems designed for expansion of both inputs and outputs. An example

Trinix

512 x 512

Trinix

512 x 512

1 - 512

1 - 512

1 - 512

32

PE 33016

used as
splitters

Frame 0

Frame 1

(unused)

Installed pre-wiring

Future output
wiring

Input slots should be terminated
using LD-33100 Loader boards

Input 1A - from upstream equipment

Output 1A - to Frame 0 Input 1

Input 1B - not used. Termination
provided by 75-ohm BNC terminator

Output 1B - to Frame 1 Input 1.
Termination provided by LD-33100
in Frame 1.

Advertising