Trinix fiber boards installation – Grass Valley Trinix NXT v.3.3.1 User Manual

Page 424

Advertising
background image

424

Trinix NXT — Installation and Service Manual

Section 13 — Trinix Fiber Option

Trinix Fiber Boards Installation

If you purchased the Trinix Fiber option with a Trinix Routing switcher, the
boards will be installed at the factory. You will only need to install the boards
on-site if they are to be used in an existing routing switcher, or used as a
replacement board.

Installing the three fiber boards requires that you remove the standard BNC
rear panel and coax Input or Output boards, if they are present. The Input or
Output boards will then be plugged in from the front of the Trinix chassis.

The three fiber boards and the SFPs are sensitive to ESD. Use static handling
precautions when installing or removing the sub-module. See ESD Protection

on page 27

for more information.

When unpacking the Fiber Rear Panels (FRP) careful attention must be paid
to the pins on the edge connector of each board. These pins can be damaged/
bent in handling or shipping. Please inspect each connector carefully
viewing the pins from various angles to make sure they are properly aligned.
If they have been damaged, please contact Grass Valley's Technical support.
Extreme care should be exercised to not damage any of the pins each time
Trinix boards are handled.

Grass Valley recommends that you install the boards in the lowest slot
number first. For example, if you had three the Fiber boards, they should be
installed in slots 1-3. If you are using a Trinix Multiviewer (TMV), install the
Fiber boards in slots after the TMV. The required Output slots for the TMV
are listed in

Table 123

. The recommended Output slot for the Fiber board are

also provided.

The TMV board may be placed in any Output slot for the 128x256 and the
512x1024 Trinix Routing switcher. See the Trinix Multiviewer Installation and
Service
manual for more information about the TMV boards.

Table 123. TMV and Fiber Board Location

Routing Switcher

Size

Required Output Slot

Numbers for the TMV

Recommended Output Slot Numbers for

the Fiber Boards

256x512

Slots 20 - 27

Slots 28 and above

128x128

*

Slots 24 and 26

Slots 28 and above

256x256

*

Slots 24, 26, 28, and 30

Slots 31 and above

512x512

*

Slots 48, 50, 52, and 54

Slots 55 and above