Output rear panel leds – Grass Valley Trinix NXT v.3.3.1 User Manual

Page 422

Advertising
background image

422

Trinix NXT — Installation and Service Manual

Section 13 — Trinix Fiber Option

Output Rear panel LEDs

Note

The reclocker will not lock when in the force-bypass mode.

Number

Color

Indication

606

Green

FPGA is loaded

637

Yellow

Active board

518

Red

Alarm Condition

910-940

Green

Power indicators

Color

Condition

Indication

None

Off

No SFPs have been installed.

Red

Solid

Indicates an SFP alarm. This can be due to several errors, such as insuffi-
cient output power or excess output power, over or under temperature, and
over or under power supply voltages.
The alarm bits can be read through the Broadlinx console port.

Green

Solid

Indicates the reclocker is locked and the SFP is recognized with no alarms.

Yellow

Solid

Indicates the reclocker is not locked and the SFP is recognized with no
alarms.

Red and Yellow

Blinking

Indicates the reclocker is not locked. Indicates an unrecognized or invalid
SFP is installed. No SFP alarms will be reported if the LED is blinking red.

Red and Green

Blinking

Indicates the reclocker is locked and the input signal may be valid. Indicates
an unrecognized or invalid SFP is installed. No SFP alarms will be reported
if the LED is blinking red.

Green and Yellow

Alternating blinking

Indicates the reclocker is in the force bypass mode, or is not reliably locked,

Green and Off

Alternating blinking

Indicates the reclocker is locked and the output is disabled. Indicates an
unrecognized or invalid SFP is installed. No SFP alarms will be reported if
the LED is blinking red.

Yellow and Off

Alternating blinking

Indicates the reclocker is not locked and the output is disabled. Indicates an
unrecognized or invalid SFP is installed. No SFP alarms will be reported if
the LED is blinking red.