3 connector designations and layouts, Connector designations and layouts – HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual

Page 12

Advertising
background image

June 2011

3 – 13

3 Connector Designations and Layouts

3.1 Connector Designations and Layouts of TNC 125, 131, 135, 145, 150, 151/155

RS-232-C/V.24 data interface, 14-pin, Amphenol

Flange socket with female insert

Pin no.

Assignment

Designation

1

GND

Chassis ground

2

Not assigned

3

Not assigned

4

Not assigned

5

RTS

Request to Send

6

DSR

Data Set Ready

7

Not assigned

8

Not assigned

9

Not assigned

10

Not assigned

11

DTR

Data Terminal Ready

12

TxD

Transmit Data

13

CTS

Clear to Send

14

RXD

Receive Data

Chassis

Ext. shield

Advertising