5 – 38

HEIDENHAIN Service Manual for Data Interfaces

EXT:

For adaptation of data transfer in standard data format and for blockwise transfer to peripheral
units.

Protocol:

Standard protocol or blockwise transfer

Adaptation via machine parameters (from MP 5000)

Data format:

Adaptation via machine parameters (from MP 5000)

Baud rate:

110 - 115 200 bauds

(depending on the hardware of the HEIDENHAIN product)

Interface parameters:

Adaptation via machine parameters (from MP 5000)

Transfer stop:

Software handshake with DC3 or hardware handshake with

RTS, selectable via machine parameters (from MP 5000)

LSV-2:

With the appropriate software (TNCremo V 3.0), the LSV-2 protocol allows various functions
such as file management, remote control, and diagnosis of the TNC to be executed from the PC.

Protocol:

Bidirectional data transfer in accordance with DIN 66019

Data format:

8 data bits, 1 stop bit, no parity

Baud rate:

110 - 115 200 bauds

(depending on the hardware of the HEIDENHAIN product)

Interface parameters:

Fixed

Transfer stop:

Software handshake via protocol