2 description of the machine parameters, Description of the machine parameters – HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual

Page 39

Advertising
background image

6 – 40

HEIDENHAIN Service Manual for Data Interfaces

6.1.2 Description of the machine parameters

Machine parameters - general information

Data format

As of TNC 151 B/Q the data format can be set in the machine parameter MP 222.

Example:

For "Blockwise transfer" with the HEIDEHAIN data transfer software in the EXT mode, the data
format must be as follows:

7 data bits, 1 stop bit, even parity, software handshake

In the "FE/ME" mode, the data format in MP 222 is not active; in this case the format is always
set to 7 data bits, 1 stop bit, even parity and software handshake.

MP 222 (5020)

Bit 0


Bit 1


Bit 2

Bit 3

Bit 4


Bit 5

Bit 7, 6

0

1


0

1

1

1

0

1

1

00

01

10

11





7 data bits (ASCII code, bit 8 = parity)

8 data bits (ASCII code, bit 8 = 0,

bit 9 = parity)

no BCC check

BCC check

Transfer stop by hardware handshake

Transfer stop by software handshake

Even character parity

Odd character parity

Character parity desired

11/2 stop bits

2 stop bits

1 stop bit

1 stop bit

7

6

5

4

3

2

1

0

Bit

1

0

1

0

1

0

0

0

Binary

128

+

32

+

8

=168

Decimal

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

=

ˆ

Advertising