8 error messages and their causes, 1 error messages at the tnc in the me mode, Error messages and their causes – HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual

Page 84: Error messages at the tnc in the me mode

Advertising
background image

April 2010

8 – 85

8 Error Messages and their Causes

8.1 Error Messages Related to the RS-232C and RS-422 Interfaces

8.1.1 Error messages at the TNC in the ME mode

WRONG OPERATING MODE

No operating mode or wrong operating mode set on the
external data medium.

FAULTY PROGRAM DATA

Wrong or faulty program data have been detected during
data transfer. The control attempted three times to read from
the magnetic tape before aborting the process.

DATA MEDIUM MISSING

No cassette has been inserted into the drive.

DATA MEDIUM EMPTY

No programs are stored on the data medium (cassette).

DATA MEDIUM WRITE-PROTECTED

The write-enable plug in the cassette is missing.

PROGAM INCOMPLETE

Data transfer was aborted before the program was
completely loaded.

EXT. IN/OUTPUT NOT READY

The DSR signal is missing at the TNC.

- ME not connected

- Transmission cable defective or incorrect

- Wrong interface assignment

ME: TAPE END

The cassette is full. To continue data transfer, turn over or
exchange the cassette.