4 emergency stop – Epson G3 Series User Manual

Page 16

Advertising
background image

Setup & Operation 1. Safety

1.4 Emergency Stop

If the Manipulator moves abnormally during operation, immediately press the Emergency
Stop switch. Stops the power supply to the motor, and the arm stops in the shortest
distance with the dynamic brake and mechanical brake.

However, avoid pressing the Emergency Stop switch unnecessarily while the Manipulator
is running normally. Otherwise, the Manipulator may hit the peripheral equipment since
the operating trajectory while the robot system stops is different from that in normal
operation.
To place the system in emergency mode during normal operation, press the Emergency
Stop switch when the Manipulator is not moving.
Refer to the Controller manual for instructions on how to wire the Emergency Stop switch
circuit.

Free running distance in emergency
The operating Manipulator cannot stop immediately after the Emergency Stop switch is
pressed.
The free running time/angle/distance of the Manipulator are shown below. However,
remember that the values vary depending on following conditions.

Weight of the end effector Weight of work piece Operating pose
Weight Speed Accel etc.

Conditions for Measurement

Accel Setting

100

Speed Setting

100

Load [kg]

3

Weight Setting

3

Joint #1

Point where the
emergency stop
signal is input

Start point of
operation

Target point

Stop point

Joint #2

Controller RC180

Manipulator

G3-25*** G3-30*** G3-35***

Joint #1 + Joint #2 [sec.]

0.8

1.2

0.6

Free running
time

Joint #3

[sec.]

0.6 0.6 0.6

Joint

#1

[deg.]

41 53 57

Joint

#2

[deg.]

13 20 20

Free running
angle

Joint #1 + Joint #2 [deg.]

54

73

77

Free running
distance

Joint

#3

G3-**1**

[mm]

95 95 95

6

G3 Rev.1

Advertising