1 max. pulse range of joint #1 – Epson G3 Series User Manual

Page 58

Advertising
background image

Setup & Operation 5. Motion Range

5.1.1 Max. Pulse Range of Joint #1

The 0 (zero) pulse position of Joint #1 is the position where Arm #1 faces toward the
positive (+) direction on the X-coordinate axis.
When the 0 pulse is a starting point, the counterclockwise pulse value is defined as the
positive (+) and the clockwise pulse value is defined as the negative (-).

+Y

+X 0 pulse

B B

A

A


Table Top Mounting

Arm

Standard

-R

-L

25

30

−125 ~ 150 / −125 ~ 150

−150 ~ 125 / −150 ~ 125

A

Max. Motion

Range

35

±

140 / ±140

−110 ~ 165/ −110 ~ 165

−165 ~ 110 / −165 ~ 110

25

30

−1019449 ~ 6990507

/ −1019449 ~ 6990507

−1747627 ~ 6262329

/ −1747627 ~ 6262329

B

Max. Pulse

Range

35

−1456356 ~ 6699236

/

−1456356 ~ 6699236

−582542 ~ 7427413

/ −582542 ~ 7427413

−2184533 ~ 5825422

/ −2184533 ~ 5825422

Multiple Mounting

Arm

Standard

-R

-L

30

±

115 / ±115

A

Max. Motion

Range

35

±

120/ ±120

−105 ~ 130 / −105 ~ 130

−130 ~ 105 / −130 ~ 105

30

−728178 ~ 5971058

/ −728178 ~ 5971058

B

Max. Pulse

Range

35

−873813 ~ 6116693

/ −873813 ~ 6116693

−436907 ~ 6407965

/ −436907 ~ 6407965

−1165085 ~ 5679787

/ −1165085 ~ 5679787

48

G3 Rev.1

Advertising