Epson G3 Series User Manual

Page 63

Advertising
background image

Setup & Operation 5. Motion Range

G3 Rev.1

53

Joint #2 Mechanical Stops

Views from the top of Arm #1

Model Arm

a

b

c

d

250 +141

° -141° +120° -120°

300 +142

° -142° +122° -122°

G3-**1S/C

350 +142

° -142° +122° -122°

300 +150

° -135° +135° -120°

G3-**1S/C-R

350 +165

° -120° +150° -105°

300 +135

° -150° +120° -135°

G3-**1S/C-L

350 +120

° -165° +105° -150°

300 +135

° -135° +115° -115°

G3-**1SM/CM

350 +142

° -142° +122° -122°

300 +120

° -160° +100° -140°

G3-**1SM/CM-R

350 +160

° -120° +140° -120°

Setting Angle

+100

° +105° +115° +120° +122° +135°

Pulse Value

2912711

3058347

3349618

3495253

3553508 3932160

Setting Angle

+141

° +142° +150° +160° +165°

Pulse Value

4106923

4136050

4369067

4660338

4805973

Setting Angle

-100°

-105°

-115°

-120°

-122°

-135°

Pulse Value

-2912711 -3058347 -3349618 -3495253 -3553508 -3932160

Setting Angle

-141°

-142°

-150°

-160°

-165°

Pulse Value

-4106923 -4136050 -4369067 -4660338 -4805973

(°: degree)

In case of Multiple Mounting, it is impossible to limit the operating range completely.
Because it may hit the wall within the setting range of mechanical stops.

)

NOTE