YASKAWA America, Inc. MP2300iec Hardware Manual YAI-SIA-IEC-2R

7 DIP Switches

7

DIP Switches

‹

Switch Settings

The DIP switch settings are only needed when the power is initially turned ON.

„

SW1

Switch

Name

Setting

Operating Mode

Default

Details

S1-6

STOP

ON

User program stopped

OFF

Stops the user program

execution.

OFF

User program running

S1-5

SUP

ON

Firmware Load

OFF

If set to ON, the

controller boots up in

the mode that can

upgrade the firmare.

See Section

23

.

OFF

Normal Operation

S1-4

INIT

ON

For diagnostic

purposes only

OFF

Always set to OFF.

OFF

For diagnostic

purposes only

S1-3

CNFG

ON

Self-configuration

Mode

OFF

Set to ON to execute

self-configuration for

connected devices and

option card.

OFF

Normal Operation

S1-2

MON

ON

Network Boot

OFF

Always leave set to

OFF.

OFF

ROM Boot

S1-1

TEST

ON

System Use

OFF

Always leave set to

OFF.

OFF

Normal Operation

SW

1

TEST

MON

CNFG

INT

SUP

STOP

NO