11 mechatrolink-ii, Mechatrolink-ii connectors, Specifications and pin arrangement – Yaskawa MP2000iec User Manual

Page 33: Terminator connections

Advertising
background image

11 MECHATROLINK-II

YASKAWA America, Inc. MP2300iec Hardware Manual YAI-SIA-IEC-2R

33

11

MECHATROLINK-II

‹

MECHATROLINK-II Connectors

The MECHATROLINK-II connector connects the MP23

͙͙͙

iec and the slave nodes via the MECHATROLINK-II

cables.

„

Specifications and Pin Arrangement

Note:

The MP2310iec only has one MECHATROLINK-II connector and includes a built-in network terminator.

„

Cable Connections between the MP23

͙͙͙iec, I/O Units or Servopacks

Use the MECHATROLINK-II cable JEPMC-W6002-

͙͙

or JEPMC-W6003-

͙͙

with a ferrite core for connection

between the MP23

͙͙͙

iec and I/O units or Servopacks.

„

Terminator Connections

Name

# of Pins

Connector Model Module

Cable

MECHATROLINK-II Connector

(M-11)

8

DUSB-AR B82-T11A-FA

DUSB-APA42-B1-C50

Pin

Signal Name

Description

Pin

Signal Name

Description

A1

B1

A2

SRD−

Signal −

B2

SRD−

Signal −

A3

SRD+

Signal +

B3

SRD+

Signal +

A4

SLD

Shield

B4

SLD

Shield

M-I/II

1

2

3

4

1

2

3

4

Shell

Shell

Pin number

Signal Name

(NC)

/DATA

DATA

SH

Shield

Shield

Signal Name

(NC)

/DATA

DATA

SH

MP2300Siec

I/O Unit or SERVOPACK

Standard model: JEPMC-W6002-

and JEPMC-W6003-

1

2

3

4

Shell

Pin number

Name

(NC)

/DATA

DATA

SH

Shield

130

Ω

JEPMC-W6022

Advertising