4.6 Application Selection

Application Presets are available to facilitate drive setup for commonly used applications. Selecting one of these Application

Presets automatically assigns functions to the input and output terminals and sets a predefined group of parameters to values

appropriate for the selected application.
In addition, the parameters most likely to be changed are assigned to the group of User Parameters, A2-01 through A2-16.

User Parameters are part of the Setup Group, which provides quicker access by eliminating the need to scroll through multiple

menus.

Note:

1. Application Presets can only be selected if all drive parameters are at their original default settings.
2. Entering a value to A1-03 to enable an Application Preset will fix that value to the parameter. The value cannot be changed without first

setting A1-03 to 2220 or 3330 to initialize the drive.

WARNING!

Sudden Movement Hazard. Confirm the drive I/O signals and external sequence before performing a test run. Setting parameter

A1-03 may automatically change the I/O terminal function from the default setting. Failure to comply may result in death or serious injury.

No.

Parameter Name

Settings

Default

A1-03

Initialize Parameters

0: No initialization (default)

1110: User Initialize (parameter values

must be stored using parameter o2-03)

2220: 2-Wire Initialize

3330: 3-Wire Initialize

5550: Terminal/Control Initialize

8008: Pump

8009: Pump w/ PI

8010: Fan

8011: Fan w/ PI

0

A1-06

Application Presets (monitor only)

0: Disabled

8: Pump

9: Pump w/ PI

10: Fan

11: Fan w/ PI

0

u

A1-03 = 8008: Pump

Table 4.7 Pump Application Parameters

Parameter

Name

Page

A1-06

Application Preset Selection (monitor only)

126

b1-01

Frequency Reference Selection

147

b1-02

Run Command Selection

148

b1-03

Stopping Method Selection

149

b1-04

Reverse Operation Selection

151

C1-01

Acceleration Time 1

176

C1-02

Deceleration Time 1

176

d1-01

Frequency Reference 1

181

E2-01

Motor Rated Current

194

L2-01

Momentary Power Loss Operation Selection

239

L5-01

Number of Auto Restart Attempts

253

L5-04

Fault Reset Interval Time

254

o1-06

User Monitor Selection Mode

266

o1-07

Second Line Monitor Selection

267

o1-08

Third Line Monitor Selection

267

u

A1-03 = 8009: Pump w/ PI

Table 4.8 Pump w/ PI Application Parameters

Parameter

Name

Page

A1-06

Application Preset Selection (monitor only)

126

b1-02

Run Command Selection

148

4.6 Application Selection

126

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual