Figure 23: 250 Series Non-volatile Read-Only Configuration Registers

250 Series Non-Volatile Read-Only Registers

Name

Address

Description

regMyGUID[3]

0x34

Factory programmed GUID used in GUID Networking

Mode

regMYGUID[2]

0x35

Factory programmed GUID used in GUID Networking

Mode

regMYGUID[1]

0x36

Factory programmed GUID used in GUID Networking

Mode

regMYGUID[0]

0x37

Factory programmed GUID used in GUID Networking

Mode

regCUSTID[1]

0x39

Factory programmed customer ID, default 0xFF

regCUSTID[0]

0x3A

Factory programmed customer ID, default 0xFF

regRELEASENUM

0x78

Holds release number indicating h/w and f/w

250 Series Non-Volatile Read / Write Registers

Name

Address Description

Factory Default

regNVHOPTABLE

0x00

Hop table

0

regNVPWRMODE

0x02

Power amplifier setting

3 (High Power)

regNVUARTDATARATE

0x03

UART data rate

0 (2400)

regNVNETWORKMODE

0x04

Sets the networking mode

4 (MAC/GUID)

regNVTXTO

0x05

UART to transmitter timeout

16 (15–16ms)

regNVMAXTXRETRY

0x07

Maximum times to retry packet

transmission

26

regNVUSECRC

0x08

Enable/Disable CRC checking

1 (Enable)

regNVUARTMTU

0x09

Minimum transmission unit

64 (64 bytes)

regNVSHOWVERSION

0x0A

Enable/disable startup

message

1 (Enabled)

regNVCSMAMODE

0x0B

Enable/Disable CSMA

1 (Enable)

regNVOPMODE

0x0D

Sets operating mode

0 (Awake)

regNVACKONWAKE

0x0E

Enable/Disable ACK sent to

UART upon wake from

1 (Enable)

regNVUSERDESTID[3]

0x0F

Destination Address for

Extended User Networking

Mode

0xFF

regNVUSERDESTID[2]

0x10

Destination Address for

Extended User Networking

Mode

0xFF

regNVUSERDESTID[1]

0x11

Destination Address for

User and Extended User

Networking Mode

0xFF

Figure 24: 250 Series Non-volatile Read / Write Configuration Registers

250 Series Non-Volatile Read / Write Registers Continued

Name

Address

Description

Factory Default

regNVUSERDESTID[0]

0x12

Destination Address for

User and Extended User

Networking Mode

0xFF

regNVUSERSRCID[3]

0x13

Source Address for Extended

User Networking Mode

0xFF

regNVUSERSRCID[2]

0x14

Source Address for Extended

User Networking Mode

0xFF

regNVUSERSRCID[1]

0x15

Source Address for User and

Extended User Networking

Mode

0xFF

regNVUSERSRCID[0]

0x16

Source Address for User and

Extended User Networking

Mode

0xFF

regNVUSERIDMASK[3]

0x17

Address Mask for Extended

User Networking Mode

0xFF

regNVUSERIDMASK[2]

0x18

Address Mask for Extended

User Networking Mode

0xFF

regNVUSERIDMASK[1]

0x19

Address Mask for User and

Extended User Networking

Mode

0xFF

regNVUSERIDMASK[0]

0x1A

Address Mask for User and

Extended User Networking

Mode

0xFF

regNVDESTGUID[3]

0x1D

GUID Networking Mode

Destination Address

0xFF

regNVDESTGUID[2]

0x1E

GUID Networking Mode

Destination Address

0xFF

regNVDESTGUID[1]

0x1F

GUID Networking Mode

Destination Address

0xFF

regNVDESTGUID[0]

0x20

GUID Networking Mode

Destination Address

0xFF

regNVEXCEPTIONMASK

0x21

Used to mask exception for

the EX line

0xFF (All)

regNVCMDHALT

0x23

Halt RF traffic when the CMD

line is low

0 (Disabled)

regNVLNAMODE

0x24

Receiver LNA gain / linearity

setting

0 (Auto)

regNVCOMPATMODE

0x25

Compatibility mode for 25 and

250 intercommunication

0 (Disabled)

regNVAUTADD

0x26

Sets automatic addressing

0 (Disabled)