Reguartdatarate, Regnetworkmode, Regnvuartdatarate – Linx Technologies TRM-915-R250 User Manual

Page 22: Regnvnetworkmode

Advertising
background image

– –

– –

38

39

Network Mode - Address = 0x4F; NV Address = 0x04
The module supports three networking modes: GUID, User, and Extended
User. For each of these modes, assured delivery (acknowledgement) and
extended preamble can be either enabled or disabled.

Figure 34 shows the command and response and Figure 35 shows the
valid settings.

Figure 35: 250 Series Network Mode Register Settings

250 Series Network Mode Register Settings

Network Mode

Meaning

0x04

GUID Networking Mode

0x06

User Networking Mode

0x07

Extended User Networking Mode

0x0C

GUID Networking Mode with Extended Preamble

0x0E

User Networking Mode with Extended Preamble

0x0F

Extended User Network Mode with Extended Preamble

0x14

GUID Networking Mode with Acknowledgement

0x16

User Networking Mode with Acknowledgement

0x17

Extended User Networking Mode with Acknowledgement

0x1C

GUID Networking Mode with Acknowledgement & Extended

Preamble

0x1E

User Networking Mode with Acknowledgement & Extended

Preamble

0x1F

Extended User Networking Mode with Acknowledgement &

Extended Preamble

Figure 34: 250 Series Network Mode Command and Response

250 Series Network Mode

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x4F

0x04

0x06

0x4F

0x04

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x4F

0x04

V1

UART Data Rate - Address = 0x4E; NV Address = 0x03
The value in regUARTDATARATE sets the data rate of the UART interface.
Changing the non-volatile register changes the data rate on the following
power-up or reset. Changing the volatile register changes the data rate
immediately following the command acknowledgement. Figure 32 shows
the command and response and Figure 33 shows the valid settings.

If the UART rate is different than the host processor UART rate then the
module will not communicate correctly. If mismatched, every rate can be
tested until the correct one is found or the module can be reset to factory
defaults.

Figure 32: 250 Series UART Data Rate Command and Response

Figure 33: 250 Series UART Data Rate Settings

250 Series UART Data Rate Register Settings

V1

Baud Rate

0x00

2,400

0x01

9,600

0x02

19,200

0x03

38,400

0x04

57,600

0x05

115,200

0x06

10,400*

0x07

31,250*

* These data rates are not supported by PC serial ports.
Selection of these rates may cause the module to fail to
respond to a PC, requiring a reset to factory defaults.

250 Series UART Data Rate

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x4E

0x03

0x06

0x4E

0x03

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x4E

0x03

V1