8. FIXTURE MENU

The control panel located on the side of the fixture allows you to
access the main menu and make all necessary adjustments to the
POWER SPOT 700™. During normal operation, tapping the
MODE” key once will access the fixture’s main menu. Once in the
main menu you can navigate through the different functions and
access the sub-menus with the Up and Down buttons. Once you
reach a field that requires adjusting, tap the ENTER button to
activate that field and use the UP and Down button to adjust the
field. Tapping the Enter button once more will confirm your setting.
Once a setting is saved the LED will briefly readout OK to confirm
a new setting has been made and locked into memory. You may
exit the main menu at any time without making any adjustments by
tapping the MODE button.


MO

DE

ENT

ER

UP

DO

WN

MODE ENTER

UP

DOWN

UP

MODE ENTER DOWN

Display

Level

1

Level

2

Level

3

Remark

D001

Define the DMX start address

TEST

Test program of all functions

AUDI

ASLW

Self-running audio program (slow)

AFST

Self-running audio program (fast)

MSTR

Master for the audio program

SVPT

Basic position for the audio program

SIZE

Size for the audio program (NORM-BIG-MIDL-

SMAL)

LAMP

Switch on/of the lamp direct at the Power Spot 700

RESE

Reset

TIME

POWR

Running time of the fixture (no destructible)

LA1

Running time of the lamp (erasable)

LA2

Running time of the lamp (no destructible)

RPAN

Reverse Pan-direction

RTLT

Reverse Tilt-direction

DMOD

NORM

DMX Mode: Defines the number of DMX channels

EXT

DMX Mode NORM has to be selected at the

moment.

SPEC

MANU

Manual drive of all device functions

LAAU

Automatic lamp start

DLOF

Switch off lamp via DMX

DMXI

Reed out actual DMX-values

DISP

D ON

Display On/Off

REV

Twist the display (also pushing Up/Down keys at

the same time)

LHEA

Function not yet in use

LBAS

Function not yet in use

DOWN

- UP

TEMP

Internal Temperature Reading