8.9.6 Fixture Temperature

TEMP

This function allows you to read out the actual fixture operating temperature.
Press the Enter button to select this function or the Mode to button to cancel
and return to the main menu. Normal operating temperature should range
between 85˚C and 95˚C. Operating temperatures between 96˚C and 104˚C
are considered critical. Temperatures above 105°C will send the fixture into
protect mode and automatically switch the lamp off, the lamp will remain off
until internal temperature drops below 95˚C. Outside surface temperature
should not exceed 45˚C.

8.9.7 Fan Control

FANS

By using this function you can choose between 4 types of fan speed
operations. Use the Up and Down buttons to select the desired fan setting,
then press Enter to accept your setting or press the Mode button to cancel
and return to the menu. The chart below will detail the different fan settings:

HIGH

The cooling fan works continuously at max. speed.

REG

This is the default fan setting. In this setting an internal thermal
sensor constantly monitors the internal operating temperature
and regulates the fan speed to coincide with the internal
temperature.

LOOF

This function is designed for environments that require low
ambient noise. In this setting the fan will operate at the lowest
speed. When the maximum internal intolerable operating
temperature is reached the lamp will automatically shut off.

LOHI

In this setting the fan will operate at the lowest speed. When the
maximum internal intolerable operating temperature is reached
the fan will automatically switch from low to high speed.