Power Spot 700 II™

©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page

24

FANS

HIGH

Reed out internal temperature

REG

Maximum cooling fan velocity

LOOF

Automatic cooling fan control

LOHI

Low cooling fan speed  lamp off

ADJU

CODE

xxxx

Use the code for entering the calibration menu (for

authorized persons only)

COL1

Calibration of the color wheel 1

COL2

Calibration of the color wheel 2

GOB1

Calibration of the gobo wheel 1

GOB2

Calibration of the gobo wheel 2

GOB3

Calibration of the gobo wheel 3

SH T

Calibration Shutter: Top side

SH B

Calibration Shutter: Bottom side

PRIS

Calibration of the prism wheel

IRIS

Calibration of the iris

POFS

Calibration of the Pan-Offsets

TOFS

Calibration of the Tilt-Offsets

CLRE

Settings in the internal memory (super-user only)

ARES

Adjust Reset (wheels stand still after the reset)

VTIL

Software version Tilt-board

VTR1

Software version driver board 1

VTR2

Software version driver board 2

VTR3

Software version driver board 3

DBUG

Function not yet in use

COAD

CODE
XXXX

Use the code for entering the calibration menu (for

authorized persons only)

COL2

Coarse calibration of the color wheel 2

COL1

Coarse calibration of the color wheel 1

DFSE

Call on the default function values

FEED

Pan/Tilt feedback (error correction) On/Off

EFLG

Correction of faults

8.1 Setting/Changing the DMX Address

After applying power to the POWER SPOT 700™ the LED will display the fixture’s
current DMX address immediately after the reset sequence. If the fixture is not
receiving a DMX signal the display will flash continuously.

D001

To set or adjust a DMX address, please follow the procedure below:

1. Switch on the POWER SPOT 700™ and wait for the fixture reset process to

finished ('RESE' will flash in the LED while fixture is in reset mode).

Advertising