8.10 Display Error and Information Messages

HEAt

This message appears if you try to switch on the lamp within 5 minutes
after having switched off (lamp too hot). The message will appear on
the display if the lamp doesn’t ignite within 20 seconds. The fixture will
store this command and automatically ignite the lamp after 5 minutes.

IG E

When igniting the lamp, the electronic ballast will examine whether the
lamp ignited or not. If the lamp does not ignite within 20 seconds, the
igniting sequence is terminated. The fixture will wait approximately 2
minutes and attempt the lamp ignition process once again. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped and
the display reads "IG E" (Ignition error).

LAER

After the ignition of the lamp was two times not successful the display
will show LAER. That means the lamp could be damaged or even
missed, the fixture is overheating or there could be a failure on the
igniter or ballast. Switch off the power supply and solve the possible
problem.

After the error "

IG E

" respectively "

LAER

" it is not anymore possible the start the

lamp via Shutter = 255. Nevertheless if a renewed ignition attempt is desired, first
run a Reset (at the Spot or over DMX). Afterwards you can try again to ignite the
lamp.

OTMP

This error message informs you that the fixture was overheating and
lamp has electronically been switched off to allow the fixture to cool to
normal operating temperatures. Please look for any possible reason
that may have caused the fixture to overheat. i.e., faulty fans, air vents
blocked or dirty, lamp broken or very old, too high ambient temperature.
Switch off the power supply and solve the possible problem.

RsER

This message informs you that one of the fixture function wasn’t able to
do its reset correct (magnetic sensor, stepping motor, driver on the
PCB, cables, etc.). Repair the defect and start the fixture again.

MD E

The Power Spot 700 has an automatic detector for the optical effects
module (software version 1.28 and later). It detects whether the Power
Spot 700 is equipped with a standard Spot module (YSDT) or a CMY
module (YCMY). In case the module is not correctly mounted or is in
need of service, the display will read MS E (Module Error)