50

12. FUSE REPLACEMENT

Caution: Always replace with the exact same type fuse, unless otherwise specified by an
authorized Elation® service technician. Replacing with anything other than the specified
part can damage your unit and will void your manufactures warranty.

Warning: If you continue to blow fuses, STOP using the fixture. Contact customer support
for further instructions, you may have to return the unit for servicing. Continuing to use the
unit may cause serious damage.

Fuse Replacement: Locate and remove the unit’s power cord from the main power
supply. Once the cord has been removed located the fuse holders located on the side
panel near the power input connection. Using a flat-head screwdriver unlock the fuse
holder from its’ housing by turning the holder in a counter-clockwise direction. Once the
fuse holder has been unlocked, pull back on the fuse holder holder to expose the fuse.
Gently pull out the bad fuse and discard of it properly and replace it with an exact match.
Reassemble in reverse order.