15627-4-0806

WIRE CHANNEL INSTALLATION

The ON/OFF/REMOTE switch with harness is

factory installed into the switch box.

After the appliance housing is installed into the

casting the wire channel can be installed.

1. Attach switch box on the left side of rear cover

with (2) 10 x 1/2" screws.

2. Route wires from ON/OFF/REMOTE switch

within wire channel.

3. Attach wire channel on the left side of the rear

cover with (4) 10 x 1/2" screws.

4. Attach the black and green (wires) female push-

ons to the TH/TP and TH (two outside male

tabs) terminals on gas valve.

5. Identify vent safety switch wire harness. The

first wire is installed into magnet section on

gas valve. The second wire is attached to the

TH/TP terminal on gas valve. Route opposite

end of vent safety switch wire harness within

(2) metal clips on exterior of rear cover. Attach

(2) 1/4" female push-ons on vent safety switch

wire harness onto (2) 1/4" male tabs on vent

safety switch which is located on the side of

draft diverter.

Figure 12

Figure 13

1. Lower valve cover on firebox.

2. Release two door latches at bottom of firebox.

3. Grasp bottom of glass frame, lift glass frame upward in order

to release glass frame from lip on top of firebox.

4. Remove logs from interior of firebox. Remove all protective

packaging from logs and interior of firebox.

5. Place front log onto two (2) front pins on inner bottom.

6. Place rear log onto two (2) rear pins on rear log support.

7. Place top log onto two (2) pins on rear log.

8. Align and place top of glass frame over lip on top of firebox.

Grasp bottom of glass frame, push inward and place glass

frame onto firebox.

9. Attach two door latches to bottom of firebox.

10. Log placement is completed.
Refer to Figure 13 for the following warning.

Warning: Failure to position the parts in accordance with

this diagram or failure to use only parts specifically approved

with this appliance may result in property damage or personal

injury.

Avertissement: Risque de dommages ou de blessures si les

pièces ne sont pas installées conformément à ce schéma et

ou si de pièces autres que celles spécifiquement approuvées

avec cet appareil sont utilisées.

LOG PLACEMENT