Introduction

Always consult your local Building Department regarding

regulations, codes or ordinances which apply to the installation

of a vented fireplace heater.
Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card

supplied with heater.

3. Installer should show owner how to start and operate heater

and thermostat.

General Information

This appliance is design certified in accordance with American

National Standard /CSA Standard ANSI Z21.88 and CSA 2.33 by

the Canadian Standards Association, as a Vented Fireplace Heater

and must be installed according to these instructions.
Any alteration of the original design, installed other than

as shown in these instructions or use with a type of gas not

shown on the rating plate is the responsibility of the person

and company making the change.
Important

All correspondence should refer to complete Model Number,

Serial Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out

and smoke will occur. To prevent triggering of smoke alarms,

ventilate the room in which the unit is installed.
Qualified Installing Agency

Installation and replacement of gas piping, gas utilization

equipment or accessories and repair and servicing of equipment

shall be performed only by a qualified agency. The term "qualified

agency" means any individual, firm, corporation or company

which either in person or through a representative is engaged in

and is responsible for (a) the installation or replacement of gas

piping or (b) the connection, installation, repair or servicing of

equipment, who is experienced in such work, familiar with all

precautions required and has complied with all the requirements

of the authority having jurisdiction.

State of Massachusetts: The installation must be made by

a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.

The installation must conform with local codes or, in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA 54.*

*Available from the American National Standards Institute, Inc., 11 West 42nd
St., New York, N.Y. 10036.

High Altitudes

When installing this unit at an elevation above 2000 feet (in the

United States) it may be necessary to decrease the input rating by

changing the existing burner orifice to a smaller size. Generally,

input should be reduced 4 percent for each 1000 feet above sea

level. However, if the heating value of the gas has been reduced,

this general rule may not apply. Check with local gas utility for

proper orifice size identification.

APPLIES TO CANADIAN MODELS ONLY FOR PROPANE

GAS.
Altitude: 0-4,500 feet (0-1370 m) without orifice change.
APPLIES TO CANADIAN MODELS ONLY FOR NATURAL

GAS.
Altitude 0-2,000 feet (0-610m) without orifice change.
Cet appareil est équipé pour des altitudes compris entre 0 et

2000 pieds (0-610m) seulement.
For installations from 610-1370 metres (2,000-4,500 ft.) the

orifice size (DMS) for natural gas is 39. See data plate for

additional information.

For high altitude installations consult the local gas distributor or

the authority having jurisdiction for proper rating methods. If the

installer must convert the unit to adjust for varying altitudes, the

information sticker (illustrated below) must be filled out by the

installer and adhered to the appliance at the time of conversion.
THE CONVERSION SHALL BE CARRIED OUT BY A MAN-

UFACTURER'S AUTHORIZED REPRESENTATIVE IN AC-

CORDANCE WITH THE REQUIREMENTS OF THE MANU-

FACTURER, PROVINCIAL OR TERRITORIAL AUTHORITIES

HAVING JURISDICTION AND IN ACCORDANCE WITH THE

REQUIREMENTS OF THE CAN/CGA-B141.1 OR CAN/CGA-

B141.2 INSTALLATION CODES.
LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFOR-

MÉMENT AUX RÉGLEMENTATION PROVINCIAUX EN

CAUSE ET AUX EXIGENCES DES CODES D'INSTALLATION

CAN/CGA-B149.

This appliance has been converted for use at an altitude of

Orifice size

Manifold Pressure

Input (Btu/h)

Fuel Type

Date of Conversion

Converted by

Cet appareil a été converti au

Injecteur

Pression à la tubulure d'alimentation

Déoit calorifique