Figure 16 shows a correct pilot flame pattern. The correct

flame will be blue and will extend beyond the thermopile.

The flame will surround the thermopile just below the tip.

A slight yellow flame may occur where the pilot flame and

main burner flame meet. Figure 17 shows an incorrect pilot

flame pattern. The incorrect pilot flame is not touching the

thermopile. This will cause the thermopile to cool. When the

thermopile cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 17

• See Troubleshooting, page 21.

Correct Pilot Flame Pattern

Figure 16

Incorrect Pilot Flame Pattern

Figure 17

Figure 18 shows a correct main burner flame pattern. Figure 19

shows an incorrect main burner flame pattern.
Air Shutter Adjustment

An air shutter adjusting screw is located on the exterior, bottom

of the inner body. Screw air shutter adjusting screw

IN to close

air shutter top (increase yellow flame). Screw air shutter adjusting

screw OUT to open air shutter top (decrease yellow flame).
If main burner flame pattern is incorrect, as shown in Figure 19

• See Troubleshooting, page 21.
Cleaning and Maintenance / Main Burner

Warning: Turn off heater and let cool before cleaning
After use, cleaning of the main burner may be required for the

proper flame. The main burner may be cleaned by applying air

pressure to the ports on the main burner.
Cleaning the Log Set and Firebox

During the annual inspection and maintenance appointment, the

service person should clean dust, lint, and any light accumulation

Correct Main Burner Flame

Figure 18

Incorrect Main Burner Flame

Figure 19

from the logs and the firebox area. An extra-soft brush should be

used on the logs as they are extremely fragile; a vacuum cleaner

may be used on the firebox. If at any time the logs cannot be

removed or installed without forcing, the cause must be found.

The logs must never be forced.
CAUTION: The ceramic logs are durable when handled and

installed properly. However, they are delicate and may be damaged

easily if not handled with care. Handling damage to the ceramic

logs is not covered by warranty.
DO NOT HANDLE LOGS WHILE THEY ARE HOT. ALLOW

PLENTY OF TIME FOR THE APPLIANCE TO COOL

COMPLETELY BEFORE HANDLING.

PLEASE NOTE

It is normal for appliances fabricated of steel to give off

some expansion and/or contraction noised during the start

up or cool down cycle. Similar noises are found with your

furnace heat exchanger or car engine.