Optional blower installation instructions – Empire Comfort Systems pmn User Manual

Page 26

Advertising
background image

Page 26

15627-4-0806

Installing Optional CIB-2 Blower

1. Loosen, but do not remove, (4) hex-head screws located on

the exterior, bottom of the appliance.

2. Position the blower assembly at the rear of the appliance.

The blower assembly has (4) keyholes for attachment to the

exterior, bottom of the appliance.

3. Place the large diameter holes in the keyholes over and behind

the (4) hex-head screws that were loosened in Step 1. Push

inward on the blower assembly to lock the keyholes into position

behind the screws. Tighten (4) hex-head screws to secure

blower assembly to exterior, bottom of the appliance.

4. Remove wire channel from rear cover by removing (4) hex-

head screws. Note: If optional blower is being installed during

initial installation of appliance, the wire channel will not be

attached to rear cover. (Refer to Wire Channel Installation,

Page 13)

5. Attach fan control to FLAT, fan control bracket (Part 9A, Page

27) with (2) 6 x 1/4" screws provided in hardware package.

6. Attach fan control with bracket onto the wire channel by using

(2) 8 x 1/4" screws provided in hardware package.

7. Route wires from fan control and ON/OFF/REMOTE switch

within wire channel.

8. When facing the rear of the appliance, align and insert fan

control with bracket into 1 3/8" x 2" opening on the left side

of the rear cover.

9. Attach wire channel to rear cover by using

(4) hex-head screws removed in Step 4.

(Refer to Wire Channel Installation, Page 13)

10. Insert AUTO/OFF/ON switch into rectangular notch on valve

bracket. Be sure to insert AUTO/OFF/ON switch with letters

(words) upright. (See wiring diagram)

11. Attach 1/4" push-on terminal from blue wire on the fan control

to the AUTO (top) tab on the switch.

12. Attach 1/4" push-on terminal from black wire to the OFF

(middle) tab on the switch.

13. Attach 1/4" push-on terminal from white wire on the fan

control to the ON (bottom) tab on the switch.

14. Installation of optional CIB-2 blower is completed.

Fan Control

The fan control is a non-adjustable automatic type. The fan

control will require between 5 and 10 minutes of main burner

operation before the fan control "closes" and activates the blower.

The blower will continue to run between 5 and 10 minutes after

the main burner shuts off, before the fan control "opens" and

deactivates the blower.

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS