Operating guidelines vent safety shutoff system – Empire Comfort Systems pmn User Manual

Page 14

Advertising
background image

Page 14

15627-4-0806

Before operating this heater, please review the safety warnings

pages at the beginning of this manual and those precautions and

warnings listed below.

1. Know what type of ignition system this model has (standing

pilot) and follow the applicable SAFETY and LIGHTING

instructions.

2. Check to ensure there are no gas leaks. If you are unsure,

turn gas off to the heater and call a service person or your gas

utility.

CAUTION: Clothing or other flammable material should not

be placed on or near the appliance.

WARNING: Children and adults should be alerted to the

hazard of high surface temperature and should stay away

to avoid burns or clothing ignition. Young children should

be carefully supervised when they are in the same room

as the appliance.

3. Tampering is DANGEROUS and voids all warranties. Any

component that is found to be faulty, must be replaced with

an approved component.

Initial Lighting (Figure 14)

Upon completing the gas line or turning the gas valve "ON" after it

has been in the "OFF" position, a small amount of air will be in the

lines. When first lighting the appliance, it will take a few minutes

for the lines to purge themselves of this air. Once the purging is

complete, the appliance will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging

if the gas valve is not turned to "OFF."
Standing Pilot Operation

1. Follow the SAFETY and LIGHTING INSTRUCTIONS for

standing pilot controls found in this manual and on labels found

attached to the appliance.

CAUTION: During the initial purging and subsequent

lightings, never allow the gas valve control knob to remain

depressed in the "pilot" position without pushing the piezo

ignitor button at least once every second.
2. During the heating season, leave the control valve knob in the

"ON" position. This will allow the pilot flame to remain lit.

Turn the burner flame on or off with the appliance ON/OFF

rocker switch, wall switch, remote control kits or 750 millivolt

wall thermostat.

NOTE: The gas control valve allows you to increase or decrease the

height of the main burner flame. The control valve has a pressure

regulator with a knob as shown in Figure 14. Rotate the knob

clockwise to "HI" to increase the flame height and counterclockwise

to "LO" to decrease the flame height.
3. When the heating season is over, turn the on/off switch to

"OFF" and the control valve to "OFF". The system, including

the pilot light, will be shut down.

Figure 14

Maximum and Minimum Input

The gas valve on the appliance allows the input to adjust between

a maximum input of 30,000 to a minimum input of 21,000 Btuh.

Please be advised, the maximum input provides the greatest amount

of yellow flame and ember glow on the log set. The minimum

input substantially decreases the yellow flame and ember glow

on the log set.

This heater must be properly connected to a venting system. This

heater is equipped with a vent safety shutoff system.

Warning:

Operation of this heater, when not connected to a properly

installed and maintained venting system or tampering

with the vent safety shutoff system, can result in carbon

monoxide (CO) poisoning and possible death.

This appliance needs fresh air for safe operation and must be

installed so there are provisions for adequate combustion and

ventilation air.
This fireplace heater is equipped with a vent safety switch. The

vent safety switch will cause gas flow to the pilot to "shut off"

due to improper venting or a blocked flue.
If the vent safety switch continues to "shut off" the gas flow to

the pilot a qualified service person must be contacted to inspect

for improper venting, blockage in the vent pipe or the vent safety

switch for being defective.

Reversible Vertical or Horizontal Draft Diverter

This fireplace heater has a reversible draft diverter. The draft

diverter is installed in the vertical position at the factory. Please

use the following steps to change the draft diverter from the vertical

position to the horizontal position.

1. Remove (8) hex-head screws located adjacent to the flue collar

on the draft diverter.

2. Rotate flue collar to the horizontal position on the draft

diverter.

3. Attach flue collar to draft diverter with (8) hex-head screws from

Step 1.

OPERATING GUIDELINES

VENT SAFETY SHUTOFF SYSTEM