Wiring – Empire Comfort Systems pmn User Manual

Page 18

Advertising
background image

Page 18

15627-4-0806

CIBV-30 ON/OFF/REMOTE Switch

CIBV-30 is equipped with an ON/OFF/REMOTE switch which

is located on the wire channel. A wire harness is attached to the

ON/OFF/REMOTE switch. The red, black and green (wires) female

push-ons attach to the ON/OFF/REMOTE switch. At the opposite

end of the wire harness, the black and green (wires) female push-

ons attach to the gas valve. An additional green wire and the red

wire, which are stripped and bare, will attach to the 750 millivolt

wall thermostat accessory, or, to one of the other accessories that

can be purchased for use with your log set.
Operation of ON/OFF/REMOTE Switch with no

Accessories

To ignite main burner, turn the control knob on the gas valve

from the PILOT position to the ON position. Turn the ON/OFF/

REMOTE switch from the OFF position to the ON position. The

additional green wire and red wire, which are stripped and bare

are not used.
Operation of ON/OFF/REMOTE Switch with Accessories

750 Millivolt Wall Thermostat

Connect the green and red, stripped and bare, wires on the ON/

OFF/REMOTE switch wire harness to the wall thermostat. Turn the

ON/OFF/REMOTE switch on the wire channel to the REMOTE

position. Set the wall thermostat to the desired temperature.
It is important to use wire of a gauge proper for the length of the

wire:

RECOMMENDED WIRE GAUGES

Maximum

Wire

Length

Gauge

1' to 10'

18

10' to 25'

16

25' to 35'

14

Wall Switch, FWS-1

Connect the green and red, stripped and bare, wires on the

ON/OFF/REMOTE switch wire harness to the wall switch.

Turn the ON/OFF/REMOTE switch on the wire channel to the

REMOTE position. Pivot the rocker switch on the FWS-1 to the

ON position.
Battery Operated Remote Control, FRBC-1 and FRBTC-1

Connect the green and red, stripped and bare, wires on the ON/

OFF/REMOTE switch wire harness to the remote receiver that

is a component in the FRBC-1 and FRBTC-1. Turn the ON/OFF/

REMOTE switch on the wire channel to the REMOTE position.

Follow instructions in the FRBC-1 and FRBTC-1 to complete

installation.

Note: If batteries fail in FRBC-1 or FRBTC-1, and immediate heat

is desired, turn the ON/OFF/REMOTE switch on wire channel

from the REMOTE position to the ON position.
Electric (120 volt) Operated Remote Control, FREC-1

Connect the green and red, stripped and bare, wires on the ON/

OFF/REMOTE switch wire harness to the wires on remote receiver

that is a component in the FREC-1. Turn the ON/OFF/REMOTE

switch on the wire channel to the REMOTE position. Follow

instructions in the FREC-1 to complete installation.
Note: If electric (120 volt) fails in FREC-1, and immediate heat

is desired, turn the ON/OFF/REMOTE switch on wire channel

from the REMOTE position to the ON position.
Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall

Thermostat Accessory and Another Accessory

Connect the green and red, stripped and bare, wires on the ON/

OFF/REMOTE switch wire harness to the 750 millivolt wall

thermostat AND to the remote receiver that is a component in the

FRBC-1, FREC-1 OR to the FWS-1, wall switch.

1. Connect (1) wire from the 750 millivolt wall thermostat and

(1) wire from appropriate accessory to the GREEN, stripped

and bare wire from the ON/OFF/REMOTE wire harness.

2. Connect (1) wire from the 750 millivolt wall thermostat and

(1) wire from appropriate accessory to the RED, stripped and

bare wire from the ON/OFF/REMOTE wire harness.

Note: When the appliance is in the MANUAL mode and the

batteries fail in the FRBC-1 or if the electric (120 volt) fails in

the FREC-1, and immediate heat is desired, turn the ON/OFF/

REMOTE switch on wire channel from the REMOTE position

to the ON position.

Manual Operation
1. Turn ON/OFF/REMOTE switch on wire channel to REMOTE

position.

2. Turn wall thermostat OFF.

3. Turn accessory, FRBC-1, FREC-1 or FWS-1, ON. Appliance

is now in the manual mode. You must turn the appliance ON

or OFF with appropriate accessory.

Wall Thermostat Operation

1. Turn the ON/OFF/REMOTE switch on wire channel to

REMOTE position.

2. Turn accessory, FRBC-1, FREC-1 or FWS-1, OFF.

3. Turn wall thermostat ON and set appropriate temperature. Wall

thermostat will cycle the appliance ON and OFF.