SIS

Programming and Control, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control

4-22

PRELIMINAR

Y

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional
description

N The

Set e-mail recipient (CR) command, sets the recipient for e-mail notifi cations. To turn e-mail notifi cations on, you

must then set the events that the switcher reports using one of more separate Set e-mail events (EM) commands.

Set e-mail recipient

EX4!

,

X4@

CR

}

Ipr

X4@

,

]

Example:

E

72,[email protected]

}

Ipr

[email protected],

]

Read e-mail recipient

EX4!

CR

}

Ipr

X4!]

N You must have fi rst set an e-mail recipient for the e-mail account number (

X4!

), using the Set e-mail recipient (CR)

command, before you can assign events to monitor with the Set e-mail events for recipient (EM) command.

Set e-mail events for
recipient

EX4!

,

X4#

,

X4$

,

X4$

, ... ,

X4$

EM

}

Ipe

X4$

,

X4$

,

X4$

, ... ,

X4$]

Response description:

Notify what?, inputs 1 - 64 (inputs above the matrix size are always 0) fans power supply

Response example (for CrossPoint 450 Plus 6464):

Response:

Notify failed and fixed

3, 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

01

Input:

02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18

52 53

51

54 55 56 57 58 59 60 61 62 63 64

Fans

Power Supplies

E-mail input 8 status

E-mail power supply and fan status

Ignore input 16

0 0 0 0 0 0 0 0 1 1 1

Read e-mail events for
recipient

EX4!

EM

}

X4$

,

X4$

,

X4$

, ... ,

X4$]

Set DHCP on or off

EX4^

DH

}

Idh

X4^]

Read DHCP status

E

DH

}

X4^]

Set serial port parameters

EX4&

*

X4*

,

X4(

,

X5)

,

X5!

CP

} X4*

,

X4(

,

X5)

,

X5!]

Read serial port parameters

EX4&

CP

}

Cpn

X4&•

Ccp

X4*

,

X4(

,

X5)

,

X5!]

Set serial port mode

EX4&

*

X5@

CY

}

Cpn

X4&•

Cty

X5@]

N The front panel Confi guration port (

X4&

= 2) is limited to the RS-232 protocol only.

Read serial port mode

EX4&

CY

}

X5@]

Set verbose mode

EX5#

CV

}

Vrb

X5#]

Read verbose mode

E

CV

}

X5#]

Read connection’s security
level

E

CK

X5$]

Commit RAM to fl ash
memory

E

1FF

}

Nvr

X5%]

Check RAM

E

FF

}

X5%]

Special Characters

The HTML language reserves certain characters for specifi c functions. The switcher
will not accept these characters as part of preset names, the switcher’s name,
passwords, or locally created fi le names.

The switcher rejects the following characters:
{space (spaces are ok for names)} + } ~ , @ = ‘ [ ] { } < > ’ “ semicolon (;)
colon (:) | \ and ?.