Preliminar y, Operation, cont’d – Extron electronic MAV Plus User Manual

Page 74

Advertising
background image

Operation, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Operation

3-44

PRELIMINAR

Y

Perform a soft reset of the switcher as follows:

1.

Press and hold the Reset button until the Reset LED blinks once (events reset),
twice (system reset), or three times (absolute reset) (fi gure 3-70).

RESET

Rx

RESET

RESET

RESET

Rx

RESET

RESET

RESET

Rx

RESET

RESET

RESET

RESET

RESET

Press and hold

the Reset button.

Release, then

immediately

press and hold.

3 seconds

Events Reset

IP Settings

Reset

Reset LED
flashes once.

1

Press and hold

the Reset button.

Release, then

immediately

press and hold.

3 seconds

Reset LED
flashes twice.

2

Absolute

Reset

Press and hold

the Reset button.

Release, then

immediately

press and hold.

3 seconds

Reset LED
flashes three
times
.

Release the

Reset button.

Release the

Reset button.

Release the

Reset button.

3

Reset LED
flashes three
times
.

3

Reset LED
flashes three
times
.

3

Reset LED
flashes three
times
.

3

Figure 3-70 — Whole switcher and absolute resets

2.

Release the Reset button and then immediately press and hold the button
until the LED fl ashes three times. Release the Reset button. Nothing happens
if the second momentary press does not occur within 1 second.