Preliminar y – Extron electronic MAV Plus User Manual

Page 35

Advertising
background image

3-5

CrossPoint 450 Plus and MAV Plus Switchers • Operation

PRELIMINAR

Y

d

Preset button —

The Preset button has two primary functions (•) and fi ve

secondary (

❏) functions:

Activates Save Preset mode to save a confi guration as a preset and
Recall Preset mode to activate a previously-defi ned preset.

Blinks when Save Preset mode is active and lights steadily when
Recall Preset mode is active.

In the I/O Group mode, select group 2. See I/O grouping on page 3-20.
In the I/O Group mode, indicate that group 2 is selected. See I/O grouping

on page 3-20.

With the Enter, View, and Esc buttons, select Serial Port Confi guration

mode. See Selecting the rear panel Remote port protocol and baud rate on
page 3-42.

Select 19200 baud for the RS-232/RS-422 port in Serial Port Confi guration

mode. See Selecting the rear panel Remote port protocol and baud rate on
page 3-42.

Indicate that the RS-232/RS-422 port is set to 19200 baud in Serial Port

Confi guration mode. See Selecting the rear panel Remote port protocol and
baud rate
on page 3-42.

e

View (

<

) button —

The View (

<

) button has two primary functions (•) and

eight secondary (

❏) functions:

Select View-Only mode that displays the current confi guration.

N View-only mode also provides a way to mute and unmute the outputs. See

Muting and unmuting video and/or audio outputs on page 3-29.

Indicate that View-Only mode is active.

In the I/O Group mode, select group 3. See I/O grouping on page 3-20.
In the I/O Group mode, indicate that group 3 is selected. See I/O grouping

on page 3-20.

(Systems with CrossPoint 450 Plus Wideband switcher BMEs) Decrease

the RGB delay of switches to the selected output. See Setting RGB delay
(systems with wideband BMEs)
on page 3-24.

(Systems with audio BMEs) Decrease the audio level of the selected

input. See Viewing and adjusting the input audio level (systems with audio
BMEs)
on page 3-32.

(Systems with audio BMEs) Decrease the volume of the selected output.

See Viewing and adjusting the output volume (systems with audio BMEs) on
page 3-35.

With the Enter, Preset, and Esc buttons, select Serial Port Confi guration

mode. See Selecting the rear panel Remote port protocol and baud rate on
page 3-42.

Select 38400 baud for the RS-232/RS-422 port in Serial Port Confi guration

mode. See Selecting the rear panel Remote port protocol and baud rate on
page 3-42.

Indicate that the RS-232/RS-422 port is set to 38400 baud in Serial Port

Confi guration mode. See Selecting the rear panel Remote port protocol and
baud rate
on page 3-42.

Advertising