Preliminar y, Programming and control, Rear panel remote port – Extron electronic MAV Plus User Manual

Page 84

Advertising
background image

CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control

4-2

SIS

Programming and Control

PRELIMINAR

Y

RS-232 and RS-422 Links

The switcher has two serial ports that can be connected to a host device such as a
computer running the HyperTerminal utility, an RS-232 capable PDA, or a control
system. These ports make serial control of the switcher possible. The two serial
ports are:

• The rear panel Remote RS-232/RS-422 port, a 9-pin D female connector

• The front panel Confi guration (RS-232) port, a 2.5 mm mini stereo jack
The default protocol for both ports is as follows:

• 9600

baud • no

parity

• 8-bit

• 1 stop bit

• no fl ow control

Rear panel Remote port

The rear panel Remote RS-232/RS-422 port (fi gure 4-1) can be confi gured for either
RS-232 or RS-422. The port can operate at the 9600, 19200, 38400, or 115200 baud
rate.

N The rear panel Remote RS-232/RS-422 port can be confi gured from the front

panel or using Simple Instruction Set (SIS) commands. See Selecting the
rear panel Remote port protocol and baud rate in chapter 3, Operation,
to confi gure the port from the front panel. See the
Set serial port parameters
command on page 4-21 to confi gure the port using an SIS command.

RS-232 Function

Pin

Function

1
2
3
4
5
6
7
8
9

TX

RX

Gnd




Not used
Transmit data
Receive data
Not used
Signal ground
Not used
Not used
Not used
Not used

TX–

RX–

Gnd

RX+

TX+

Not used
Transmit data (–)
Receive data (–)
Not used
Signal ground
Not used
Receive data (+)
Transmit data (+)
Not used

RS-422

5

1

9

6

RS232/RS422

REMO

TE

Figure 4-1 — Remote connector pin assignments