4-13

CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control

PRELIMINAR

Y

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional
description

Save, recall, and directly write presets

N • If the user tries to recall a preset that is not saved, the matrix switcher responds with the error code E11.

• If the room is nonexistent, the matrix switcher responds with the error code E21.

• The following characters are invalid in preset names: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

Save current the current
confi guration as a global
preset

X1!

,

Spr

X1!]

Command character is a
comma.

Example:

9,

Spr09

]

Save current ties as preset 9.

Direct write process —

N The

direct write of a global preset command should always be preceded by a clear global preset command of that

same preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied output)
remains unchanged unless overwritten or cleared.

If you do not clear a global preset number before you directly write a global preset to that number, ties that are part of
the previous version of the specifi ed preset can unexpectedly become part of the newly-created preset.

Clear a global preset

E

+

X1!

P0*!

}

Spr

X1!]

Clear all ties in preset

X1!

.

Directly write a global
preset

E

+

X1!

P

X@

*

X#

!

X@

*

X#

%

X@

*

X#

$ ...

X@

*

X#

&

}

Enter as many ties as are
valid for this model. The
tie all (!), tie RGBHV (&), tie
video (%), and tie audio ($)
commands are all valid.

Spr

X1!]

Example:

E

+27P0*!

}

Spr27

]

Brackets are shown to
separate ties for clarity only.
Create global preset 27,
which ties video and audio
input 22 to output 5,
RGBHV input 15 to output 29,
video input 13 to output 26,
and audio input 3 to output 8.

E

+27P22*5!15*29%13*26$3*8&

Spr27

]

Recall a global preset

X1!

.

Rpr

X1!]

Command character is a
period.

Example:

5.

Rpr

X1!]

Recall preset 5, which
becomes the current
confi guration.

Write room outputs

EX*

,

Y!

,

Y@

,

Y#

, ...,

Y/

MR

}

See notes.

Mpr

X*

,

Y!

,

Y@

,

Y#

, ...,

Y/]

N

Each

Y`

is an output.

• A room can contain a maximum of 16 outputs (

Y`

s).

• An output can belong to one room only.

• The maximum number of rooms (

X*

) is 10.

• If no room name is assigned, the dafault name is “Room #

X*•Y!

,

•Y@

,

•Y#

”.

Example:

E

8,3,04,5,6MR

}

Mpr8,03,04,05,06

]

Outputs 3, 4, 5, and 6 are
assigned to room 8.

Read room outputs

EX*

MR

}

X2!

,

Y!

,

Y@

,

Y#

, ...,

Y/]

Example:

E

3MR

}

Class 1,01,02,08,09

]

Outputs 1, 2, 8, and 9 are
assigned to room 3, which is
named “Class 1”.

Save current confi guration
as a room preset

X*

*

X1@

,

Rmm

X*•

Spr

X1@]

Command character is a
comma.

Example:

3*9,

Rmm03

Spr09

]

Save the current
confi guration as preset 9 for
room 3.