set maclock static

Enterasys D-Series CLI Reference

17-57

Example

This example shows how to remove a MAC from the list of static MACs allowed to communicate 
on port 

ge

.3.2: 

D2(rw)->clear maclock 0e-03-ef-d8-44-55 ge.3.2

set maclock static

Use this command to set the maximum number of static MAC addresses allowed per port. Static 
MACs are administratively defined. 

Syntax

set maclock static port-string value

Parameters

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to set the maximum number of allowable static MACs to 2 on 

ge

.3.1: 

D2(rw)->set maclock static ge.3.1 2

clear maclock static

Use this command to reset the number of static MAC addresses allowed per port to the default 
value of 20.

Syntax

clear maclock static port-string

Parameters

Defaults

None.

port‐string

Specifies the port on which to set the maximum number of static MACs 
allowed. For a detailed description of possible port‐string values, refer to 

Port String Syntax Used in the CLI

” on page 6‐1.

value

Specifies the maximum number of static MAC addresses allowed per 
port. Valid values are 0 to 20.

port‐string

Specifies the port on which to reset number of static MAC addresses 
allowed. For a detailed description of possible port‐string values, refer to 

Port String Syntax Used in the CLI

” on page 6‐1.