Configure system menu

Figure 7. Configure System menu

System options

Field

Selection Description

Name

16 Char.

(Input) Configuration name.

Used for saving the current configuration to file.

Device

16 Char.

(Input) Device name

(displayed in all menus at the lower left)

Info

.

64 Char.

(Input) Detailed information about the current configuration

Sub Matrix

Y/N

Y – This switch is configured according to a master switch and remotely controlled

No configuration possible.

N – No slave mode

Load Default

Y/N

Y – Upon “Power On” or “Restart” the switch will boot with the Default

configuration.

N – Upon “Power On” or “Restart” the switch will boot with the last configuration.

Auto Save

Y/N

Y – Switch saves periodically the current configuration into flash.

N – No automatic saving

Enable
COM Echo

Y/N

Y – Switch sends echoes of all performed switch commands

N – No Echoes.

Lock
COM Ports

Y/N

Y – While an OSD is open, all commands via external interfaces are rejected

(LAN, serial).

N – No rejection

Baud rate
kBaud

Numerical
Value

Select a predefined Baud rate for the serial control port (default: 115.2 kBaud)

Slave Matrix

Y/N

Y - Allows a second Orion unit to automatically be switched to the same port as

the master unit

N – No synchronization

Master Address IP Address

Assigned master unit IP address that secondary units will synchronize to.

(Entered on secondary unit’s OSD)