* May be 0 (no breaker) or 1 (with breaker).

TABLE 13: Electrical Data - (For Single Source Power Supply) - Copper Wire 1 Ø - 208/230-1-60

Models

MA

Heat Kit - Single

Phase*

Heater

Amps

Field Wiring

Min. Circuit Ampacity

Max. O.C.P.

1

Amps/Type

75°C Wire Size - AWG

240V

208V

240V

208V

240V

208V

240V

08BN21

4HK*6500206

10.4

13.03

14.88

15

15

14

14

4HK*6500506

20.0

23.42

26.88

30

30

10

10

4HK*6500806

31.3

35.60

41.00

40

45

8

8

4HK*6501006

40.0

45.08

51.88

50

60

8

6

4HK16501306

54.2

60.4

69.6

70

70

4

4

12BN21

4HK*6500506

20.0

25.79

29.38

30

30

10

10

4HK*6500806

31.3

37.98

43.50

40

45

8

8

4HK*6501006

40.0

47.46

54.38

50

60

8

6

4HK16501306

54.2

61.3

72.1

70

90

4

3

4HK165N1506

60.0

69.13

79.38

70

90

4

3

14DN21

4HK*6500506

20.0

24.29

28.00

30

30

8

10

4HK*6500806

31.3

36.48

42.13

40

45

8

8

4HK*6501006

40.0

45.96

53.00

50

60

8

6

4HK16501506

60.0

67.63

78.00

70

90

4

3

4HK16501806

73.3

82.07

94.63

90

100

4

3

4HK16502006

80.0

89.29

103.00

100

110

3

2

16CN21

4HK*6500506

20.0

26.17

30.00

30

30

8

8

4HK*6500806

31.3

38.35

44.13

40

45

8

8

4HK*6501006

40.0

47.83

55.00

50

60

8

6

4HK16501306

54.2

65.2

74.80

70

80

4

2

4HK16501506

60.0

69.50

80.00

70

90

4

3

4HK16501806

73.3

83.94

96.63

90

100

4

3

4HK16502006

80.0

91.17

105.00

100

110

3

2

20DN21

4HK*6500806

31.3

42.60

48.38

45

50

8

8

4HK*6501006

40.0

52.08

59.25

60

60

8

6

4HK16501306

54.2

67.7

77.00

70

80

4

2

4HK16501506

60.0

73.75

84.25

90

90

3

3

4HK16501806

73.3

88.19

100.88

90

110

3

2

4HK16502006

80.0

95.42

109.25

100

125

3

2

4HK16502506

100.0

117.08

134.25

125

150

1

1/0

1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.

TABLE 14: Electrical Data - 3 Ø - 208/230-3-60

Models

MA

Heat Kit -

Three Phase

Max.

Static

Min.

Speed

Tap

Total Heat

1

KW Staging

KW

MBH

W1 Only

W2 Only

W1 + W2

208V 240V 208V 240V 208V 240V 208V 240V 208V 240V

08B

4HK06501025

0.5

Hi

7.2

9.6

24.6

32.8

7.2

9.6

7.2

9.6

7.2

9.6

12B

4HK06501025

0.5

Med

7.2

9.6

24.6

32.8

7.2

9.6

7.2

9.6

7.2

9.6

4HK065N1525

0.5

Hi

10.8

14.4

36.9

49.1

10.8

14.4

10.8

14.4

10.8

14.4

14D

4HK06501025

0.5

Med

7.2

9.6

24.6

32.8

7.2

9.6

7.2

9.6

7.2

9.6

4HK06501525

0.5

Med

10.8

14.4

36.9

49.1

10.8

14.4

10.8

14.4

10.8

14.4

4HK06501825

0.5

Hi

12.9

17.2

44.7

58.7

12.9

17.2

12.9

17.2

12.9

17.2

16C

4HK06501025

0.5

Med

7.2

9.6

24.6

32.8

7.2

9.6

7.2

9.6

7.2

9.6

4HK06501525

0.5

Med

10.8

14.4

36.9

49.1

10.8

14.4

10.8

14.4

10.8

14.4

4HK06501825

0.5

Hi

12.9

17.2

44.7

58.7

12.9

17.2

12.9

17.2

12.9

17.2

20D

4HK06501025

0.5

Lo

7.2

9.6

24.6

32.8

7.2

9.6

7.2

9.6

7.2

9.6

4HK06501525

0.5

Med

10.8

14.4

36.9

49.1

10.8

14.4

10.8

14.4

10.8

14.4

4HK16501825

0.5

Med

12.9

17.2

44.7

58.7

12.9

17.2

12.9

17.2

12.9

17.2

4HK16502525

0.5

Med

18.0

24.0

61.4

81.4

9.0

12.0

18.0

24.0

18.0

24.0