Duct work should be fabricated and installed in accordance with local

and/or national codes. This includes the standards of the National Fire

Protection Association for Installation of Air-Conditioning and Ventilat-

ing Systems, NFPA No. 90B.

AIR FILTERS

Air filters and filter racks must be field supplied.

.

SUSPENSION KITS

A suspension kit is available. Models 1BH0601 (unit size 018-060) is

designed specifically for the units contained in this instruction (upflow

application only). For installation of these accessory kits, see the

instructions packed with the kit.

HORIZONTAL SUSPENSION

For suspension of these units in horizontal applications, it is recom-

mended to use angle steel support brackets with threaded rods, sup-

porting the units from the bottom, at the locations shown in Figure 4.

SECTION IV: ELECTRIC HEATER

INSTALLATION

If the air handler requires electric heat, install the electric heat kit

according to the installation instructions included with the kit. After

installing the kit, mark the air handler nameplate to designate the heater

kit that was installed. If no heater is installed, mark the name plate

appropriately to indicate that no heat kit is installed.
The HEAT ENABLE jumper (See Figure 5) must be moved to the HEAT

position to enable operation of the heater.
Use only 4HK heater kits, as listed on Air Handler name plate and in

these Instructions. Use data from Tables 11 through 18 for information

on required minimum motor speed tap to be used for heating operation,

maximum over-current protection device required and minimum electri-

cal supply wiring size required for listed combination of Air Handler and

Heater Kit.
For Upflow, Downflow and Horizontal right hand applications the kits

can be installed without modification.
Field modification is required for Horizontal left-hand airflow application

only. Follow instructions with heater for modification.

Equipment should never be operated without filters.

Units

(Nominal Tons)

Dimension

WW

XX

YY

1-1/2 - 3 Ton

16”

48”

22”

FIGURE 5: Typical Horizontal Installation

WW

XX

SUSPENSION SUPPORT LOCATIONS FOR HORIZONTAL APPLICATIONS

2

1-1/2

MIN. 1-1/2” x 1-1/2” Angle

Recommended length

26” minimum

with 2” clearance on

both sides of Air Handler

MIN. 3/8”

THREADED ROD

YY

3-1/2 - 5 Ton

24”

53” - 58”

22”

FIGURE 5: Typical Horizontal Installation

FIGURE 6: Control Board

HEAT ENABLE

JUMPER

HUM OUT

RELAY OUTPUT

EAC RELAY
OUTPUT

LOW FAN

RELAY OUTPUT

SPARE
JUMPER

HUM STAT JUMPER

MODE JUMPER

FUSE