Thermo Pride Air Handler MA User Manual

Page 31

Advertising
background image

15

TABLE 15: Air Handler Air Flow Data

HIGH/LOW SPEED COOLING AND HEAT PUMP AIRFLOW

CFM

m³/min

JUMPER SETTINGS

12B

12D

12B

12D

High

Low

High

Low

High

Low

High

Low

COOL Tap

ADJ Tap

1385

896

1411

907

39.2

25.4

39.9

25.7

A

B

1137

745

1159

767

32.2

21.1

32.8

21.7

B

B

1203

777

1227

799

34.1

22.0

34.7

22.6

A

A

1019

650

1007

662

28.8

18.4

28.5

18.7

B

A

1085

690

1083

716

30.7

19.5

30.7

20.3

A

C

943

615

958

629

26.7

17.4

27.1

17.8

C

B

889

585

908

603

25.2

16.6

25.7

17.1

B

C

746

493

767

537

21.1

14.0

21.7

15.2

D

B

817

537

840

568

23.1

15.2

23.8

16.1

C

A

646

467

660

516

18.3

13.2

18.7

14.6

D

A

738

481

780

532

20.9

13.6

22.1

15.1

C

C

580

465

603

517

16.4

13.2

17.1

14.6

D

C

16C

20D

16C

20D

JUMPER SETTINGS

High

Low

High

Low

High

Low

High

Low

COOL Tap

ADJ Tap

2005

1433

2404

1579

56.8

40.6

68.1

44.7

A

B

1768

1145

2022

1313

50.1

32.4

57.2

37.2

B

B

2009

1299

2167

1388

56.9

36.8

61.3

39.3

A

A

1615

1040

1801

1159

45.7

29.4

51.0

32.8

B

A

1787

1159

1924

1256

50.6

32.8

54.5

35.6

A

C

1524

988

1818

1175

43.1

28.0

51.5

33.3

C

B

1445

940

1620

1024

40.9

26.6

45.9

29.0

B

C

1350

883

1638

1049

38.2

25.0

46.4

29.7

D

B

1384

906

1628

1030

39.2

25.6

46.1

29.2

C

A

1215

800

1442

929

34.4

22.6

40.8

26.3

D

A

1236

810

1434

911

35.0

22.9

40.6

25.8

C

C

1086

716

1305

859

30.7

20.3

36.9

24.3

D

C

HIGH / LOW SPEED ELECTRIC HEAT AIRFLOW

CFM

m³/min

JUMPER SETTINGS

12B

12D

12B

12D

High

Low

High

Low

High

Low

High

Low

HEAT Tap

ADJ Tap

1385

900

1411

913

39.2

25.5

39.9

25.8

A

N / A

1228

795

1258

817

34.8

22.5

35.6

23.1

B

N / A

1137

748

1159

769

32.2

21.2

32.8

21.8

C

N / A

917

603

928

619

26.0

17.1

26.3

17.5

D

N / A

16C

20D

16C

20D

JUMPER SETTINGS

High

Low

High

Low

High

Low

High

Low

HEAT Tap

ADJ Tap

2006

1411

2408

1515

56.8

39.9

68.2

42.9

A

N / A

1868

1243

2218

1285

52.9

35.2

62.8

36.4

B

N / A

1468

983

1902

1070

41.6

27.8

53.8

30.3

C

N / A

1248

840

1407

823

35.3

23.8

39.8

23.3

D

N / A

1. Airflow at nominal voltage, bottom return at 0.5 external static pressure, tested without filter installed, dry coil conditions.

2. These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure.

3. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static.

4. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.

5. Both the COOL and the ADJUST tap must be set to obtain the cooling airflow desired (CFM).

6. The ADJ tap does not affect the HEAT tap setting.

7. Low speed cooling used only with two stage outdoor units. (Speed is preset to 65% of high speed).

8. Dehumidification speed is 85% of jumper selected COOL tap and ADJUST tap.

9. When operating in both heat pump and electric heat modes, the airflow (CFM) will be per HEAT Tap CFM values only.

10. At some settings, LOW COOL and/or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain models of electronic air

cleaners. Consult the instructions for the electronic air cleaner for further details.

11. Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (i.e.: 12 Flashes is 1200 CFM) – blinks are approximate +/- 10% of actual CFM.

Advertising
This manual is related to the following products: