Floor Mounting the Luminaire

All luminaires included in this manual are designed to sit directly on its base in a floor installation
application. When used in this type of application, be sure to leave enough space around the luminaire
to allow proper, uninterrupted airflow for cooling and movement.

Connecting Data and Power

A maximum of 32 luminaires may be connected in any one DMX data link.

Note:

This maximum limit applies to the luminaire "daisy chain" only. Your system or console may

require fewer luminaires on a single data link path. Consult your console documentation for more
information.

To connect power and data:

Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN

connectors of remaining luminaires in link.

Step 3. At last luminaire in link, install male termination connector at DATA THRU connector.

(Luminaires and other devices on the same DMX chain may not function properly without
termination.)

Figure 2-1: Data Link

Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with

luminaire head and yoke movement.

VL6000 Beam Luminaire Channel Requirements*

DMX512 Channels

Description

Menu Display

23 Channels

16-Bit Mode

(default)

16

**DMX terminator required for last fixture on DMX line.

Data In

Termination**

Data Thru

AC In

AC In

AC In